2mA/2mA Voltage Transformer

Structure parameters

ZMPT112

Current-type Voltage transformer

small sizehigh accuracygood consistencyfor voltage and power measurement

  

Structural parameters

                                  Wiring according to the drawings, homonymous ends diagonal, the input and output can be reversed

 

                                         Front view                         Bottom view

 


The main technical parameters

Model

ZMPT112

Rated   input current

2mA

Rated   output current

2mA

turns ratio

1000:1000

phase angle error

≤45'(input 2mAsampling resistor 50Ω

linear range

0~1000V      0~10mAsampling resistor 50Ω

linearity

0.2%20%dot~120%dot

Permissible error

-0.6% ≤ f ≤0%input 2mAsampling resistance 50Ω

isolation voltage

3000V

application

current and power measurement

Encapsulation

Epoxy

installation

PCB   mountingPin Length>3mm

operating   temperature

-40℃~+85℃


Direction for use

                               Figure Ⅰ                                         FigureⅡ

 

1. The typical usage of the product is for the active output ( FigureⅠ). R'is a limiting resistor,R is a sampling resistor.

2. The product can be directly through the resistance sampling , easy to use ( FigureⅡ).

 


Product Inquiry

2mA/2mA PCB mounting Voltage Transformer 1000:1000 used for UPS

2mA/2mA PCB mounting Voltage Transformer 1000:1000

2mA/2mA Voltage Transformer

2mA/2mA Voltage Transformer

2mA/2mA current-type Voltage Transformer